ACS724 & ACS725 High-Accuracy Current Sensors

Allegro MicroSystems ACS724 and ACS725 High-Accuracy Current Sensors are AEC-Q101 qualified and offer a 5V operation supply voltage and a 120kHz analog output. These sensors are provided in multiple compact packages with a high level of integration that fits various application needs, and they feature a precise, low-offset, linear Hall sensor circuit with a copper conduction path located near the surface of the die. Applied current flows through this copper conduction path, generating a magnetic field sensed by the integrated Hall IC and converted into a proportional voltage. The current is sensed differentially to reject stray fields, improving accuracy in magnetically noisy environments. Allegro MicroSystems ACS724 and ACS725 High-Accuracy Current Sensors are provided in compact, low-profile surface-mount SOIC8 (LC) and custom SOIC16 packages (MA and MC).

Ergebnisse: 52
Auswählen Bild Teile-Nr. Herst. Beschreibung Datenblatt Verfügbarkeit Preis (EUR) Ergebnisse in der Tabelle nach dem Einheitspreis bei Ihrer Menge filtern. Menge RoHS ECAD Model Nennstrom Art des Sensors Ansprechzeit Präzision Frequenzbereich Betriebsversorgungsspannung Art der Ausgabe
Allegro MicroSystems Stromsensoren für Plattenmontage ACS724LLC-30AB-T 2.060Auf Lager
9.000erwartet ab 15.07.2026
Min.: 1
Mult.: 1
Rolle: 3.000

30 A Current Sense 4 us 2 % 120 kHz 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage ACS724LLC-30AU-T 6.136Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

30 A Current Sense 4 us 2 % 120 kHz 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage HIGH ACCURACY 3.3V SOIC8 CURRENT SENSOR 6.429Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

50 A Current Sense 4 us 2 % 120 kHz 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR 4.041Auf Lager
Min.: 1
Mult.: 1
Rolle: 1.000

30 A Current Sense 4 us 120 kHz 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage HIGH ACCURACY, 3.3V CURRENT SENSOR 4.232Auf Lager
Min.: 1
Mult.: 1
Rolle: 1.000

20 A Current Sense 4 us 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage HIGH ACCURACY 3.3V SOIC8 CURRENT SENSOR 2.748Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

5 A Current Sense 4 us 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage DIFFERENTIAL HALL INTEGRATED CURRENT SEN 3.582Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

10 A Current Sense 4 us 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage DIFFERENTIAL HALL INTEGRATED CURRENT SENSOR IC FOR 3.3V PLATFORMS 4.944Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

20 A Current Sense 4 us 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage DIFFERENTIAL HALL INTEGRATED CURRENT SENSOR IC FOR 3.3V PLATFORMS 2.583Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

20 A Current Sense 4 us 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR 6.239Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

30 A Current Sense 4 us 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR 5.982Auf Lager
Min.: 1
Mult.: 1
Rolle: 1.000

30 A Current Sense 4 us 2 % 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage HIGH ACCURACY 3.3V SOIC8 CURRENT SENSOR 6.120Auf Lager
Min.: 1
Mult.: 1
Rolle: 3.000

Current Sense 4 us 120 kHz 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage HIGH ACCURACY, 3.3V CURRENT SENSOR 3.442Auf Lager
Min.: 1
Mult.: 1
Rolle: 1.000

40 A Current Sense 4 us 2 % 125 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR 733Auf Lager
Min.: 1
Mult.: 1
Rolle: 800
65 A Current Sense 4 us 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR 241Auf Lager
Min.: 1
Mult.: 1
Rolle: 1.000

30 A Current Sense 4 us 2 % 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 10 Wochen
Min.: 4.800
Mult.: 4.800
Rolle: 800
20 A Current Sense 4 us 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 24 Wochen
Min.: 6.000
Mult.: 6.000
Rolle: 1.000

30 A Current Sense 4 us 120 kHz 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 16 Wochen
Min.: 4.800
Mult.: 4.800
Rolle: 800
30 A Current Sense 4 us 4.5 V to 5.5 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage HIGH ACCURACY, 3.3V CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 24 Wochen
Min.: 6.000
Mult.: 6.000
Rolle: 1.000

20 A Current Sense 4 us 2 % 120 kHz 3 V to 3.6 V Analog
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 24 Wochen
Min.: 6.000
Mult.: 6.000
Rolle: 1.000

50 A Current Sense 4 us 2 % 120 kHz 3 V to 3.6 V Analog

Allegro MicroSystems Stromsensoren für Plattenmontage AUTOMOTIVE GRADE, GALVANICALLY ISOLATED CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 24 Wochen
Min.: 6.000
Mult.: 6.000
100 A Current Sense 4 us 2 % 120 kHz 4.5 V to 5.5 V Ratiometric
Allegro MicroSystems ACS725LLCTR-10AB-S
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 10 Wochen
Min.: 9.000
Mult.: 9.000
Allegro MicroSystems ACS725LLCTR-20AU-S
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 24 Wochen
Min.: 9.000
Mult.: 9.000
Allegro MicroSystems ACS725LLCTR-30AB-S
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 24 Wochen
Min.: 9.000
Mult.: 9.000
Allegro MicroSystems ACS725LLCTR-30AU-S
Allegro MicroSystems Stromsensoren für Plattenmontage CURRENT SENSOR Nicht-auf-Lager-Vorlaufzeit 24 Wochen
Min.: 9.000
Mult.: 9.000