CASR Board Mount Current Transducers

LEM CASR Board Mount Current Transducers are specifically designed for accurate electronic measurement of DC, AC, and pulsed currents, covering a range from 1.5A to 75A RMS. These sensors provide galvanic isolation between the primary and secondary circuits, ensuring enhanced safety and performance. Built with compact Fluxgate-based technology, the LEM CASR current sensors operate with a single +5V supply and exhibit minimal offset and gain drift. The CASR sensors also offer an extended measuring range up to three times the nominal primary current (Ipn), making them highly versatile. Additionally, these transducers are designed for direct PCB mounting, featuring three primary pins for efficient handling of small current measurements from 2A to 50A RMS.

Ergebnisse: 10
Auswählen Bild Teile-Nr. Herst. Beschreibung Datenblatt Verfügbarkeit Preis (EUR) Ergebnisse in der Tabelle nach dem Einheitspreis bei Ihrer Menge filtern. Menge RoHS ECAD Model Nennstrom Art des Sensors Ansprechzeit Präzision Frequenzbereich Betriebsversorgungsspannung Art der Ausgabe
LEM Stromsensoren für Plattenmontage 184Auf Lager
Min.: 1
Mult.: 1
6 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Current transducer CASR series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 565Auf Lager
Min.: 1
Mult.: 1

25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Current transducer CASR series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 403Auf Lager
Min.: 1
Mult.: 1

50 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Current transducer CASR series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit.
3.149Auf Bestellung
Min.: 1
Mult.: 1

15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Current transducer CASR series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit.
362erwartet ab 06.04.2026
Min.: 1
Mult.: 1

6 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Nicht-auf-Lager-Vorlaufzeit 14 Wochen
Min.: 200
Mult.: 200
15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Nicht-auf-Lager-Vorlaufzeit 14 Wochen
Min.: 200
Mult.: 200
15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Nicht-auf-Lager-Vorlaufzeit 14 Wochen
Min.: 200
Mult.: 200
25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Nicht-auf-Lager-Vorlaufzeit 14 Wochen
Min.: 200
Mult.: 200
25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Stromsensoren für Plattenmontage Nicht-auf-Lager-Vorlaufzeit 14 Wochen
Min.: 200
Mult.: 200
50 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog